SMJH 85
SMINOX H 150/4
SYMH 8
DESCRIPTION AND USAGE AREAS
This type package booster sets are systems used in apartments, villas, schools, hospitals, factories and public housing. The sound level of our BOOSTER SETS is below 84 dB. This type package booster sets manufactured at frequencies of 50 Hz and 60 Hz. Turkey Booster Manufacturers
JET POMPALI PAKET HİDROFORLAR | ||||||||||||
TİP | KW | HP | V Mono | V Tri | ÇALIŞMA BASINCI | m³/h Max | TANK HACMİ | W mm | L mm | H mm | DAİRE SAYISI | KAT SAYISI |
SMJH 85 (FLATÖR) | 0,65 | 0,85 | 220 | 380 | 2 – 4 | 3,5 | 24 | 350 | 440 | 590 | 4 | 4 |
SMJKH 100 (FLATÖR) | 0,75 | 1 | 220 | – | 2 – 4,5 | 3,5 | 24 | 350 | 440 | 590 | 5 | 5 |
SMJH 150 (FLATÖR) | 1,1 | 1,5 | 220 | 380 | 3 – 5 | 4,5 | 50 | 350 | 630 | 720 | 10 | 5 |
SMJH 220 (FLATÖR) | 1,6 | 2,2 | 220 | 380 | 4 – 6 | 6 | 100 | 475 | 845 | 810 | 16 | 8 |
PASLANMAZ SANTRİFÜJ POMPALI PAKET HİDROFORLAR | ||||||||||||
TİP | KW | HP | V Mono | V Tri | ÇALIŞMA BASINCI | m³/h Max | TANK HACMİ | W mm | L mm | H mm | DAİRE SAYISI | KAT SAYISI |
SMINOX H 150/4 | 1,1 | 1,5 | 220 | 380 | 3 – 5 | 5,8 | 50 | 350 | 650 | 720 | 12 | 5 |
SMINOX H 150/4 T | 1,1 | 1,5 | 220 | 380 | 3 – 5 | 5,8 | 50 | 350 | 650 | 720 | 12 | 5 |
YATAY KADEMELİ PAKET HİDROFORLAR | ||||||||||||
TİP | KW | HP | V Mono | V Tri | ÇALIŞMA BASINCI | m³/h Max | TANK HACMİ | W mm | L mm | H mm | DAİRE SAYISI | KAT SAYISI |
SYMH8-220/6 SYMTH8-220/6 (FLATÖR + PANO) | 1,6 | 2,2 | 220 | 380 | 5 – 7 | 8 | 100 | 505 | 795 | 840 | 18 – 10 | 6 – 10 |
SYMTH8-300/8 (FLATÖR + PANO) | 2,2 | 3 | – | 380 | 8 – 10 | 8 | 100 | 505 | 800 | 840 | 24 – 20 | 10 – 14 |
SYMH12-220/4 SYMTH12-220/4 (FLATÖR + PANO) | 1,6 | 2,2 | 220 | 380 | 3 – 5 | 12 | 100 | 505 | 785 | 840 | 34 – 16 | 6 – 8 |
SYMTH12-300/6 (FLATÖR + PANO) | 2,2 | 3 | – | 380 | 5 – 7 | 12 | 100 | 505 | 790 | 840 | 32 – 18 | 10 – 13 |
SMKTA750
SMKTB750
SMKTC750
DESCRIPTION AND USAGE AREAS
This type of BOOSTER SETS offers suction up to 4 m. Water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and frequency-controlled water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SMKTA550 | 1×4 | 380 | 50 | 2900 | 500 | 550 | 600 | 1½ | 1½ | 10 – 15 | 70 – 50 | 45 – 70 | 14 – 8 |
SMKTB550 | 2×4 | 380 | 50 | 2900 | 950 | 790 | 700 | 1½ | 2 | 20 – 30 | 70 – 50 | 90 – 140 | 14 – 8 |
SMKTC550 | 3×4 | 380 | 50 | 2900 | 1310 | 790 | 700 | 1½ | 2 | 30 – 45 | 70 – 50 | 135 – 210 | 14 – 8 |
SMKTA750 | 1×5,5 | 380 | 50 | 2900 | 500 | 550 | 600 | 1½ | 1½ | 10 – 15 | 80 – 50 | 45 – 70 | 17 – 8 |
SMKTB750 | 2×5,5 | 380 | 50 | 2900 | 950 | 790 | 700 | 1½ | 2 | 20 – 30 | 80 – 50 | 90 – 140 | 17 – 8 |
SMKTC750 | 3×5,5 | 380 | 50 | 2900 | 1310 | 790 | 700 | 1½ | 2 | 30 – 45 | 80 – 50 | 135 – 210 | 17 – 8 |
SMKTA550/2 | 1×4 | 380 | 50 | 2900 | 500 | 550 | 600 | 2 | 2 | 10 – 25 | 55 – 30 | 45 – 115 | 10 – 3 |
SMKTB550/2 | 2×4 | 380 | 50 | 2900 | 950 | 850 | 700 | 2 | 3 | 20 – 50 | 55 – 30 | 90 – 230 | 10 – 3 |
SMKTC550/2 | 3×4 | 380 | 50 | 2900 | 1310 | 850 | 700 | 2 | 3 | 30 – 75 | 55 – 30 | 135 – 345 | 10 – 3 |
SMKTA750/2 | 1×5,5 | 380 | 50 | 2900 | 500 | 550 | 600 | 2 | 2 | 10 – 25 | 60 – 40 | 45 – 115 | 11 – 6 |
SMKTB750/2 | 2×5,5 | 380 | 50 | 2900 | 950 | 850 | 700 | 2 | 3 | 20 – 50 | 60 – 40 | 90 – 230 | 11 – 6 |
SMKTC750/2 | 3×5,5 | 380 | 50 | 2900 | 1310 | 850 | 700 | 2 | 3 | 30 – 75 | 60 – 40 | 135 – 345 | 11 – 6 |
SMINOX12A220/2
SMINOX12B220/2
SMINOX12C220/2
DESCRIPTION AND USAGE AREAS
This type water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. It is suitable for use in hygienic environments because all surfaces that are in contact with water are full stainless. Consult your company for any multi-pump systems and frequency-controlled water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | |||||||||||||
TİP | KW | V Mono | V Tri | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SMINOX12A220/2 | 1×1,6 | 220 | 380 | 50 | 2900 | 480 | 520 | 495 | 1¼ | 1¼ | 9 – 3 | 27 – 45 | 40 – 14 | 2 – 7 |
SMINOX12B220/2 | 2×1,6 | 220 | 380 | 50 | 2900 | 850 | 520 | 700 | 1¼ | 2″ | 18 – 6 | 27 – 45 | 80 – 28 | 2 – 7 |
SMINOX12C220/2 | 3×1,6 | 220 | 380 | 50 | 2900 | 1155 | 520 | 700 | 1¼ | 2″ | 27 – 9 | 27 – 45 | 120 – 42 | 2 – 7 |
SMINOX12A300/3T | 1×2,2 | – | 380 | 50 | 2900 | 480 | 520 | 495 | 1¼ | 1¼ | 9 – 3 | 35 – 60 | 40 – 14 | 4 – 11 |
SMINOX12B300/3T | 2×2,2 | – | 380 | 50 | 2900 | 850 | 520 | 700 | 1¼ | 2″ | 18 – 6 | 35 – 60 | 80 – 28 | 4 – 11 |
SMINOX12C300/3T | 3×2,2 | – | 380 | 50 | 2900 | 1155 | 520 | 700 | 1¼ | 2″ | 27 – 9 | 35 – 60 | 120 – 42 | 4 – 11 |
SHTP8A
SHTP8B
SHTP8C
DESCRIPTION AND USAGE AREAS
This type stainless booster sets offers suction up to 4 m. Water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. It is suitable for use in hygienic environments because all surfaces that are in contact with water are full stainless. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SHTP8A-220/8 | 1×1,6 | 380 | 50 | 2900 | 360 | 506 | 9+8 | 1½ | 1½ | 4 – 5 | 60 – 50 | 18 – 24 | 11 – 8 |
SHTP8B-220/8 | 2×1,6 | 380 | 50 | 2900 | 1000 | 750 | 867 | 2″ | 2″ | 8 – 10 | 60 – 50 | 36 – 48 | 11 – 8 |
SHTP8C-220/8 | 3×1,6 | 380 | 50 | 2900 | 1300 | 750 | 867 | 2″ | 2″ | 12 – 15 | 60 – 50 | 54 – 72 | 11 – 8 |
SHTP8A-300/10 | 1×2,2 | 380 | 50 | 2900 | 360 | 405 | 927 | 1½ | 1½ | 4 – 5 | 70 – 60 | 18 – 24 | 14 – 11 |
SHTP8B-300/10 | 2×2,2 | 380 | 50 | 2900 | 1000 | 750 | 927 | 2″ | 2″ | 8 – 10 | 70 – 60 | 36 – 48 | 14 – 11 |
SHTP8C-300/10 | 3×2,2 | 380 | 50 | 2900 | 1300 | 750 | 927 | 2″ | 2″ | 12 – 15 | 70 – 60 | 54 – 72 | 14 – 11 |
SHTP8A-400/12 | 1×3 | 380 | 50 | 2900 | 360 | 405 | 987 | 1½ | 1½ | 4 – 5 | 80 – 70 | 18 – 24 | 17 – 14 |
SHTP8B-400/12 | 2×3 | 380 | 50 | 2900 | 1000 | 750 | 987 | 2″ | 2″ | 8 – 10 | 80 – 70 | 36 – 48 | 17 – 14 |
SHTP8C-400/12 | 3×3 | 380 | 50 | 2900 | 1300 | 750 | 987 | 2″ | 2″ | 12 – 15 | 80 – 70 | 54 – 72 | 17 – 14 |
SHTP16A-550/8 | 1×4 | 380 | 50 | 2900 | 360 | 405 | 960 | 1½ | 1½ | 2,5 – 10 | 60 – 45 | 24 – 48 | 11 – 7 |
SHTP16B-550/8 | 2×4 | 380 | 50 | 2900 | 1000 | 800 | 960 | 3″ | 2½ | 5 – 20 | 60 – 45 | 48 – 96 | 11 – 7 |
SHTP16C-550/8 | 3×4 | 380 | 50 | 2900 | 1300 | 800 | 960 | 3″ | 2½ | 7,5 – 30 | 60 – 45 | 72 – 144 | 11 – 7 |
SHTP16A-550/10 | 1×4 | 380 | 50 | 2900 | 360 | 405 | 1020 | 1½ | 1½ | 5 – 10 | 100 – 75 | 24 – 48 | 23 – 15 |
SHTP16B-550/10 | 2×4 | 380 | 50 | 2900 | 1000 | 800 | 1020 | 3″ | 2½ | 10 – 20 | 100 – 75 | 48 – 96 | 23 – 15 |
SHTP16C-550/10 | 3×4 | 380 | 50 | 2900 | 1300 | 800 | 1020 | 3″ | 2½ | 15 – 30 | 100 – 75 | 72 – 144 | 23 – 15 |
SHTP16A-750/12 | 1×5,5 | 380 | 50 | 2900 | 360 | 405 | 1081 | 1½ | 1½ | 6 – 10 | 120 – 85 | 28 – 48 | 28 – 19 |
SHTP16B-750/12 | 2×5,5 | 380 | 50 | 2900 | 1000 | 800 | 1081 | 3″ | 2½ | 12 – 20 | 120 – 85 | 56 – 96 | 28 – 19 |
SHTP16C-750/12 | 3×5,5 | 380 | 50 | 2900 | 1300 | 800 | 1081 | 3″ | 2½ | 18 – 30 | 120 – 85 | 85 – 144 | 28 – 19 |
SHTP16A-750/14 | 1×5,5 | 380 | 50 | 2900 | 360 | 405 | 1042 | 1½ | 1½ | 7 – 10 | 130 – 95 | 32 – 48 | 32 – 22 |
SHTP16B-750/14 | 2×5,5 | 380 | 50 | 2900 | 1000 | 800 | 1042 | 3″ | 2½ | 14 – 20 | 130 – 95 | 64 – 96 | 32 – 22 |
SHTP16C-750/14 | 3×5,5 | 380 | 50 | 2900 | 1300 | 800 | 1042 | 3″ | 2½ | 21 – 30 | 130 – 95 | 96 – 144 | 32 – 22 |
SHTPD8A
SHTPD8B
SHTPD8C
DESCRIPTION AND USAGE AREAS
This type inline booster sets offers suction up to 4 m. Water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. It is suitable for use in hygienic environments because all surfaces that are in contact with water are full stainless. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SHTPD8A-220/8 | 1×1,6 | 380 | 50 | 2900 | 360 | 506 | 9+8 | 1½ | 1½ | 4 – 5 | 60 – 50 | 18 – 24 | 11 – 8 |
SHTPD8B-220/8 | 2×1,6 | 380 | 50 | 2900 | 1000 | 750 | 867 | 2″ | 2″ | 8 – 10 | 60 – 50 | 36 – 48 | 11 – 8 |
SHTPD8C-220/8 | 3×1,6 | 380 | 50 | 2900 | 1300 | 750 | 867 | 2″ | 2″ | 12 – 15 | 60 – 50 | 54 – 72 | 11 – 8 |
SHTPD8A-300/10 | 1×2,2 | 380 | 50 | 2900 | 360 | 405 | 927 | 1½ | 1½ | 4 – 5 | 70 – 60 | 18 – 24 | 14 – 11 |
SHTPD8B-300/10 | 2×2,2 | 380 | 50 | 2900 | 1000 | 750 | 927 | 2″ | 2″ | 8 – 10 | 70 – 60 | 36 – 48 | 14 – 11 |
SHTPD8C-300/10 | 3×2,2 | 380 | 50 | 2900 | 1300 | 750 | 927 | 2″ | 2″ | 12 – 15 | 70 – 60 | 54 – 72 | 14 – 11 |
SHTPD8A-400/12 | 1×3 | 380 | 50 | 2900 | 360 | 405 | 987 | 1½ | 1½ | 4 – 5 | 80 – 70 | 18 – 24 | 17 – 14 |
SHTPD8B-400/12 | 2×3 | 380 | 50 | 2900 | 1000 | 750 | 987 | 2″ | 2″ | 8 – 10 | 80 – 70 | 36 – 48 | 17 – 14 |
SHTPD8C-400/12 | 3×3 | 380 | 50 | 2900 | 1300 | 750 | 987 | 2″ | 2″ | 12 – 15 | 80 – 70 | 54 – 72 | 17 – 14 |
SHTPD16A-550/8 | 1×4 | 380 | 50 | 2900 | 360 | 405 | 960 | 1½ | 1½ | 2,5 – 10 | 60 – 45 | 24 – 48 | 11 – 7 |
SHTPD16B-550/8 | 2×4 | 380 | 50 | 2900 | 1000 | 800 | 960 | 3″ | 2½ | 5 – 20 | 60 – 45 | 48 – 96 | 11 – 7 |
SHTPD16C-550/8 | 3×4 | 380 | 50 | 2900 | 1300 | 800 | 960 | 3″ | 2½ | 7,5 – 30 | 60 – 45 | 72 – 144 | 11 – 7 |
SHTPD16A-550/10 | 1×4 | 380 | 50 | 2900 | 360 | 405 | 1020 | 1½ | 1½ | 5 – 10 | 100 – 75 | 24 – 48 | 23 – 15 |
SHTPD16B-550/10 | 2×4 | 380 | 50 | 2900 | 1000 | 800 | 1020 | 3″ | 2½ | 10 – 20 | 100 – 75 | 48 – 96 | 23 – 15 |
SHTPD16C-550/10 | 3×4 | 380 | 50 | 2900 | 1300 | 800 | 1020 | 3″ | 2½ | 15 – 30 | 100 – 75 | 72 – 144 | 23 – 15 |
SHTPD16A-750/12 | 1×5,5 | 380 | 50 | 2900 | 360 | 405 | 1081 | 1½ | 1½ | 6 – 10 | 120 – 85 | 28 – 48 | 28 – 19 |
SHTPD16B-750/12 | 2×5,5 | 380 | 50 | 2900 | 1000 | 800 | 1081 | 3″ | 2½ | 12 – 20 | 120 – 85 | 56 – 96 | 28 – 19 |
SHTPD16C-750/12 | 3×5,5 | 380 | 50 | 2900 | 1300 | 800 | 1081 | 3″ | 2½ | 18 – 30 | 120 – 85 | 85 – 144 | 28 – 19 |
SHTPD16A-750/14 | 1×5,5 | 380 | 50 | 2900 | 360 | 405 | 1042 | 1½ | 1½ | 7 – 10 | 130 – 95 | 32 – 48 | 32 – 22 |
SHTPD16B-750/14 | 2×5,5 | 380 | 50 | 2900 | 1000 | 800 | 1042 | 3″ | 2½ | 14 – 20 | 130 – 95 | 64 – 96 | 32 – 22 |
SHTPD16C-750/14 | 3×5,5 | 380 | 50 | 2900 | 1300 | 800 | 1042 | 3″ | 2½ | 21 – 30 | 130 – 95 | 96 – 144 | 32 – 22 |
SHT6 A
SHT6 B
SHT6 C
DESCRIPTION AND USAGE AREAS
Multi stage water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | |||||||||||||
TİP | KW | V Mono | V Tri | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SHT6A-100/6 | 1×0,75 | 220 | 380 | 50 | 2900 | 340 | 290 | 570 | 1¼ | 1″ | 2,5 – 4,0 | 42 – 25 | 12 – 15 | 3 – 6 |
SHT6B-100/6 | 2×0,75 | 220 | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 5,0 – 8,0 | 42 – 25 | 24 – 30 | 3 – 6 |
SHT6C-100/6 | 3×0,75 | 220 | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 7,5 – 12 | 42 – 25 | 36 – 45 | 3 – 6 |
SHT6A-150/8 | 1×1,1 | 220 | 380 | 50 | 2900 | 340 | 290 | 570 | 1¼ | 1″ | 2,5 – 4,2 | 50 – 30 | 12 – 20 | 9 – 4 |
SHT6B-150/8 | 2×1,1 | 220 | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 5,0 – 8,4 | 50 – 30 | 24 – 40 | 9 – 4 |
SHT6C-150/8 | 3×1,1 | 220 | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 7,5 – 12,6 | 50 – 30 | 35 – 60 | 9 – 4 |
SHT6A-180/10 | 1×1,35 | – | 380 | 50 | 2900 | 340 | 290 | 610 | 1¼ | 1″ | 2,6 – 3,4 | 60 – 50 | 12 – 16 | 12 – 8 |
SHT6B-180/10 | 2×1,35 | – | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 5,2 – 6,8 | 60 – 50 | 24 – 32 | 12 – 8 |
SHT6C-180/10 | 3×1,35 | – | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 7,6 – 10,2 | 60 – 50 | 36 – 48 | 12 – 8 |
SHT8 A
SHT8 B
SHT8 C
DESCRIPTION AND USAGE AREAS
Multi stage water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | |||||||||||||
TİP | KW | V Mono | V Tri | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SHT8A-220/6 | 1×1,6 | 220 | 380 | 50 | 2900 | 350 | 290 | 610 | 1¼ | 1¼ | 3,5 – 6 | 70 – 40 | 16 – 28 | 14 – 6 |
SHT8B-220/6 | 2×1,6 | 220 | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 7 – 12 | 70 – 40 | 33 – 56 | 14 – 6 |
SHT8C-220/6 | 3×1,6 | 220 | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 10,5 – 18 | 70 – 40 | 48 – 86 | 14 – 6 |
SHT8A-300/8 | 1×2,2 | – | 380 | 50 | 2900 | 350 | 290 | 610 | 1¼ | 1¼ | 4 – 5,5 | 80 – 60 | 18 – 26 | 17 – 10 |
SHT8B-300/8 | 2×2,2 | – | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 8 – 11 | 80 – 60 | 36 – 52 | 17 – 10 |
SHT8C-300/8 | 3×2,2 | – | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 12 – 16 | 80 – 60 | 54 – 76 | 17 – 10 |
SHT8A-400/10 | 1×3 | – | 380 | 50 | 2900 | 350 | 290 | 640 | 1¼ | 1¼ | 4 – 5 | 90 – 80 | 18 – 24 | 20 – 17 |
SHT8B-400/10 | 2×3 | – | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 8 – 10 | 90 – 80 | 36 – 47 | 20 – 17 |
SHT8C-400/10 | 3×3 | – | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 12 – 15 | 90 – 80 | 54 – 70 | 20 – 17 |
SHT12 A
SHT12 B
SHT12 C
DESCRIPTION AND USAGE AREAS
Multi stage water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | |||||||||||||
TİP | KW | V Mono | V Tri | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SHT12A-220/4 | 1×1,6 | 220 | 380 | 50 | 2900 | 350 | 290 | 580 | 1¼ | 1¼ | 5 – 9 | 50 – 30 | 24 – 43 | 9 – 4 |
SHT12B-220/4 | 2×1,6 | 220 | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 10 – 18 | 50 – 30 | 47 – 86 | 9 – 4 |
SHT12C-220/4 | 3×1,6 | 220 | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 15 – 27 | 50 – 30 | 70 – 120 | 9 – 4 |
SHT12A-300/6 | 1×2,2 | – | 380 | 50 | 2900 | 350 | 290 | 580 | 1¼ | 1¼ | 4 – 7,5 | 70 – 50 | 19 – 35 | 14 – 9 |
SHT12B-300/6 | 2×2,2 | – | 380 | 50 | 2900 | 940 | 465 | 820 | 2″ | 2″ | 8 – 15 | 70 – 50 | 38 – 70 | 14 – 9 |
SHT12C-300/6 | 3×2,2 | – | 380 | 50 | 2900 | 1190 | 465 | 820 | 2″ | 2″ | 12 – 22,5 | 70 – 50 | 56 – 106 | 14 – 9 |
SHT12A-400/7 | 1×3 | – | 380 | 50 | 2900 | 350 | 290 | 585 | 1¼ | 1¼ | 3,5 – 7 | 80 – 70 | 17 – 33 | 17 – 14 |
SHT12B-400/7 | 2×3 | – | 380 | 50 | 2900 | 940 | 465 | 585 | 2″ | 2″ | 7 – 14 | 80 – 70 | 32 – 66 | 17 – 14 |
SHT12C-400/7 | 3×3 | – | 380 | 50 | 2900 | 1190 | 465 | 585 | 2″ | 2″ | 10 – 21 | 80 – 70 | 45 – 100 | 17 – 14 |
SHT16 A
SHT16 B
SHT16 C
DESCRIPTION AND USAGE AREAS
Multi stage water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SHT16A-550/4 | 1×4 | 380 | 50 | 2900 | 370 | 330 | 620 | 1½ | 1¼ | 4 – 16 | 70 – 40 | 19 – 76 | 14 – 5 |
SHT16B-550/4 | 2×4 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 8 – 32 | 70 – 40 | 38 – 150 | 14 – 5 |
SHT16C-550/4 | 3×4 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 12 – 48 | 70 – 40 | 57 – 225 | 14 – 5 |
SHT16A-550/5 | 1×4 | 380 | 50 | 2900 | 370 | 330 | 660 | 1½ | 1¼ | 8 – 11 | 90 – 60 | 38 – 52 | 17 – 11 |
SHT16B-550/5 | 2×4 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 16 – 22 | 90 – 60 | 76 – 104 | 17 – 11 |
SHT16C-550/5 | 3×4 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 24 – 33 | 90 – 60 | 112 – 152 | 17 – 11 |
SHT16A-750/6 | 1×5,5 | 380 | 50 | 2900 | 370 | 330 | 700 | 1½ | 1¼ | 7 – 14 | 100 – 80 | 32 – 64 | 23 – 17 |
SHT16B-750/6 | 2×5,5 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 14 – 28 | 100 – 80 | 64 – 128 | 23 – 17 |
SHT16C-750/6 | 3×5,5 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 21 – 42 | 100 – 80 | 100 – 200 | 23 – 17 |
SHT16A-750/7 | 1×5,5 | 380 | 50 | 2900 | 370 | 330 | 740 | 1½ | 1¼ | 6 – 13 | 110 – 90 | 28 – 60 | 25 – 20 |
SHT16B-750/7 | 2×5,5 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 12 – 26 | 110 – 90 | 56 – 120 | 25 – 20 |
SHT16C-750/7 | 3×5,5 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 18 – 39 | 110 – 90 | 81 – 180 | 25 – 20 |
SHT16A-850/8 | 1×6,3 | 380 | 50 | 2900 | 370 | 330 | 740 | 1½ | 1¼ | 6 – 13 | 120 – 100 | 28 – 60 | 28 – 23 |
SHT16B-850/8 | 2×6,3 | 380 | 50 | 2900 | 940 | 550 | 820 | 3″ | 2½ | 12 – 26 | 120 – 100 | 56 – 120 | 28 – 23 |
SHT16C-850/8 | 3×6,3 | 380 | 50 | 2900 | 1190 | 550 | 820 | 3″ | 2½ | 18 – 39 | 120 – 100 | 81 – 184 | 28 – 23 |
SHT24 A
SHT24 B
SHT24 C
DESCRIPTION AND USAGE AREAS
Multi stage water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SHT24A-750/4 | 1×5,5 | 380 | 50 | 2900 | 750 | 517 | 1065 | 2″ | 2″ | 9 – 20 | 50 – 30 | 42 – 95 | 8 – 3 |
SHT24B-750/4 | 2×5,5 | 380 | 50 | 2900 | 1105 | 567 | 1065 | 3″ | 2½ | 18 – 40 | 50 – 30 | 84 – 190 | 8 – 3 |
SHT24C-750/4 | 3×5,5 | 380 | 50 | 2900 | 1450 | 717 | 1065 | DN 100 | 3″ | 27 – 60 | 50 – 30 | 126 – 285 | 8 – 3 |
SHT24A-750/5 | 1×5,5 | 380 | 50 | 2900 | 750 | 517 | 1115 | 2″ | 2″ | 10 – 19 | 60 – 40 | 48 – 89 | 11 – 6 |
SHT24B-750/5 | 2×5,5 | 380 | 50 | 2900 | 1105 | 567 | 1115 | 3″ | 2½ | 20 – 38 | 60 – 40 | 96 – 178 | 11 – 6 |
SHT24C-750/5 | 3×5,5 | 380 | 50 | 2900 | 1450 | 717 | 1115 | DN 100 | 3″ | 30 – 57 | 60 – 40 | 144 – 267 | 11 – 6 |
SHT24A-750/6 | 1×5,5 | 380 | 50 | 2900 | 750 | 517 | 1165 | 2″ | 2″ | 11 – 18 | 70 – 50 | 52 – 85 | 14 – 8 |
SHT24B-750/6 | 2×5,5 | 380 | 50 | 2900 | 1105 | 567 | 1165 | 3″ | 2½ | 22 – 36 | 70 – 50 | 104 – 170 | 14 – 8 |
SHT24C-750/6 | 3×5,5 | 380 | 50 | 2900 | 1450 | 717 | 1165 | DN 100 | 3″ | 33 – 54 | 70 – 50 | 156 – 255 | 14 – 8 |
SHT24A-1000/7 | 1×7,5 | 380 | 50 | 2900 | 750 | 517 | 1215 | 2″ | 2″ | 7 – 17 | 90 – 65 | 33 – 80 | 20 – 12 |
SHT24B-1000/7 | 2×7,5 | 380 | 50 | 2900 | 1105 | 567 | 1215 | 3″ | 2½ | 14 – 37 | 90 – 65 | 66 – 160 | 20 – 12 |
SHT24C-1000/7 | 3×7,5 | 380 | 50 | 2900 | 1450 | 717 | 1215 | DN 100 | 3″ | 21 – 51 | 90 – 65 | 99 – 240 | 20 – 12 |
SHT24A-1000/8 | 1×7,5 | 380 | 50 | 2900 | 750 | 517 | 1265 | 2″ | 2″ | 9 – 16 | 100 – 80 | 42 – 76 | 23 – 17 |
SHT24B-1000/8 | 2×7,5 | 380 | 50 | 2900 | 1105 | 567 | 1265 | 3″ | 2½ | 18 – 32 | 100 – 80 | 84 – 152 | 23 – 17 |
SHT24C-1000/8 | 3×7,5 | 380 | 50 | 2900 | 1450 | 717 | 1265 | DN 100 | 3″ | 27 – 47 | 100 – 80 | 126 – 228 | 23 – 17 |
SHT34 A
SHT34 B
SHT34 C
DESCRIPTION AND USAGE AREAS
Vertical shaft water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss | DAİRE SAYISI | KAT SAYISI |
SHT34A-750/4 | 1×5,5 | 380 | 50 | 2900 | 750 | 517 | 1065 | 2″ | 2″ | 16 – 29 | 60 – 40 | 76 – 136 | 11 – 6 |
SHT34B-750/4 | 2×5,5 | 380 | 50 | 2900 | 1105 | 567 | 1065 | 3″ | 2½ | 32 – 58 | 60 – 40 | 152 – 272 | 11 – 6 |
SHT34C-750/4 | 3×5,5 | 380 | 50 | 2900 | 1450 | 717 | 1065 | DN 100 | 3″ | 48 – 87 | 60 – 40 | 228 – 408 | 11 – 6 |
SHT34A-1000/5 | 1×7,5 | 380 | 50 | 2900 | 750 | 517 | 1115 | 2″ | 2″ | 12 – 27 | 80 – 60 | 56 – 127 | 17 – 11 |
SHT34B-1000/5 | 2×7,5 | 380 | 50 | 2900 | 1105 | 567 | 1115 | 3″ | 2½ | 36 – 54 | 80 – 60 | 112 – 256 | 17 – 11 |
SHT34C-1000/5 | 3×7,5 | 380 | 50 | 2900 | 1405 | 717 | 1115 | DN 100 | 3″ | 36 – 81 | 80 – 60 | 168 – 384 | 17 – 11 |
SHT34A-1500/6 | 1×11 | 380 | 50 | 2900 | 750 | 517 | 1165 | 2″ | 2″ | 16 – 28 | 90 – 70 | 76 – 130 | 20 – 14 |
SHT34B-1500/6 | 2×11 | 380 | 50 | 2900 | 1105 | 567 | 1165 | 3″ | 2½ | 32 – 56 | 90 – 70 | 152 – 260 | 20 – 14 |
SHT34C-1500/6 | 3×11 | 380 | 50 | 2900 | 1450 | 717 | 1165 | DN 100 | 3″ | 48 – 84 | 90 – 70 | 228 – 390 | 20 – 14 |
SHT34A-1500/7 | 1×11 | 380 | 50 | 2900 | 750 | 517 | 1215 | 2″ | 2″ | 22 – 30 | 100 – 80 | 104 – 140 | 23 – 17 |
SHT34B-1500/7 | 2×11 | 380 | 50 | 2900 | 1105 | 567 | 1215 | 3″ | 2½ | 44 – 60 | 100 – 80 | 210 – 280 | 23 – 17 |
SHT34C-1500/7 | 3×11 | 380 | 50 | 2900 | 1450 | 717 | 1215 | DN 100 | 3″ | 66 – 90 | 100 – 80 | 312 – 420 | 23 – 17 |
SHT32 A
SHT32 B
SHT32 C
DESCRIPTION AND USAGE AREAS
Multi stage water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss |
SHT32A/2 | 1×3 | 380 | 50 | 2900 | 335 | 800 | 1119 | 1½ | 1¼ | 13 – 19 | 40 – 20 |
SHT32B/2 | 2×3 | 380 | 50 | 2900 | 675 | 1415 | 1119 | 3″ | 2½ | 26 – 38 | 40 – 20 |
SHT32C/2 | 3×3 | 380 | 50 | 2900 | 1106 | 1415 | 1119 | 4″ | 3″ | 39 – 57 | 40 – 20 |
SHT32A/3 | 1×4 | 380 | 50 | 2900 | 335 | 800 | 1209 | 1½ | 1¼ | 10 – 18 | 70 – 30 |
SHT32B/3 | 2×4 | 380 | 50 | 2900 | 675 | 1015 | 1209 | 4″ | 3″ | 30 – 54 | 70 – 30 |
SHT32C/3 | 3×4 | 380 | 50 | 2900 | 1106 | 1015 | 1209 | 4″ | 3″ | 30 – 54 | 70 – 30 |
SHT32A/4 | 1×5,5 | 380 | 50 | 2900 | 335 | 800 | 1274 | 1½ | 1¼ | 10 – 19 | 90 – 60 |
SHT32B/4 | 2×5,5 | 380 | 50 | 2900 | 675 | 1015 | 1274 | 3″ | 2½ | 20 – 38 | 90 – 60 |
SHT32C/4 | 3×5,5 | 380 | 50 | 2900 | 1106 | 1015 | 1274 | 4″ | 3″ | 30 – 57 | 90 – 60 |
SHT32A/5 | 1×7,5 | 380 | 50 | 2900 | 335 | 800 | 1285 | 1½ | 1¼ | 12 – 17 | 110 – 70 |
SHT32B/5 | 2×7,5 | 380 | 50 | 2900 | 675 | 1015 | 1385 | 3″ | 2½ | 24 – 34 | 110 – 70 |
SHT32C/5 | 3×7,5 | 380 | 50 | 2900 | 1106 | 1015 | 1385 | 4″ | 3″ | 36 – 51 | 110 – 70 |
SHT32A/6 | 1×11 | 380 | 50 | 2900 | 335 | 800 | 1479 | 1½ | 1¼ | 12 – 18 | 130 – 90 |
SHT32B/6 | 2×11 | 380 | 50 | 2900 | 675 | 1015 | 1479 | 3″ | 2½ | 24 – 36 | 130 – 90 |
SHT32C/6 | 3×11 | 380 | 50 | 2900 | 1106 | 1014 | 1479 | 4″ | 3″ | 36 – 54 | 130 – 90 |
SHT40 A
SHT40 B
SHT40 C
DESCRIPTION AND USAGE AREAS
Vertical shaft water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss |
SHT40A/2 | 1×7,5 | 380 | 50 | 2900 | 335 | 800 | 1255 | 2″ | 1½ | 32 – 38 | 40 – 30 |
SHT40B/2 | 2×7,5 | 380 | 50 | 2900 | 675 | 1415 | 1255 | 3″ | 3″ | 64 – 76 | 40 – 30 |
SHT40C/2 | 3×7,5 | 380 | 50 | 2900 | 1106 | 1415 | 1255 | 5″ | 4″ | 96 – 114 | 40 – 30 |
SHT40A/3 | 1×11 | 380 | 50 | 2900 | 335 | 800 | 1356 | 2″ | 1½ | 20 – 33 | 80 – 60 |
SHT40B/3 | 2×11 | 380 | 50 | 2900 | 375 | 1015 | 1356 | 3″ | 3″ | 40 – 66 | 80 – 60 |
SHT40C/3 | 3×11 | 380 | 50 | 2900 | 1106 | 101 | 1356 | 5″ | 4″ | 60 – 99 | 80 – 60 |
SHT40A/4 | 1×15 | 380 | 50 | 2900 | 335 | 800 | 1511 | 2″ | 1½ | 20 – 34 | 110 – 80 |
SHT40B/4 | 2×15 | 380 | 50 | 2900 | 675 | 1015 | 1511 | 3″ | 3″ | 40 – 68 | 110 – 80 |
SHT40C/4 | 3×15 | 380 | 50 | 2900 | 1106 | 1015 | 1511 | 5″ | 4″ | 60 – 102 | 110 – 80 |
SHT40A/5 | 1×18,5 | 380 | 50 | 2900 | 335 | 800 | 1610 | 2″ | 1½ | 32 – 35 | 130 – 90 |
SHT40B/5 | 2×18,5 | 380 | 50 | 2900 | 675 | 1015 | 1610 | 3″ | 3″ | 64 – 70 | 130 – 90 |
SHT40C/5 | 3×18,5 | 380 | 50 | 2900 | 1106 | 1015 | 1610 | 5″ | 4″ | 96 – 105 | 130 – 90 |
SHT50 A
SHT50 B
SHT50 C
DESCRIPTION AND USAGE AREAS
Multi stage water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss |
SHTA50/2 | 1×11 | 380 | 50 | 2900 | 435 | 800 | 1440 | 2½ | 2″ | 27 – 48 | 65 – 50 |
SHTB50/2 | 2×11 | 380 | 50 | 2900 | 875 | 1515 | 1440 | 5″ | 4″ | 54 – 96 | 65 – 50 |
SHTC50/2 | 3×11 | 380 | 50 | 2900 | 1350 | 1515 | 1440 | 6″ | 5″ | 81 – 144 | 65 – 50 |
SHTA50/2 | 1×15 | 380 | 50 | 2900 | 435 | 800 | 1500 | 2½ | 2″ | 28 – 50 | 80 – 60 |
SHTB50/2 | 2×15 | 380 | 50 | 2900 | 875 | 1515 | 1500 | 5″ | 4″ | 56 – 100 | 80 – 60 |
SHTC50/2 | 3×15 | 380 | 50 | 2900 | 1350 | 1515 | 1500 | 6″ | 5″ | 84 – 150 | 80 – 60 |
SHTA50/3 | 1×18,5 | 380 | 50 | 2900 | 435 | 800 | 1590 | 2½ | 2″ | 27 – 55 | 100 – 70 |
SHTB50/3 | 2×18,5 | 380 | 50 | 2900 | 875 | 1015 | 1590 | 5″ | 4″ | 54 – 110 | 100 – 70 |
SHTC50/3 | 3×18,5 | 380 | 50 | 2900 | 1350 | 1015 | 1590 | 6″ | 5″ | 81 – 165 | 100 – 70 |
SHTA50/3 | 1×22 | 380 | 50 | 2900 | 435 | 800 | 1670 | 2½ | 2″ | 20 – 52 | 120 – 90 |
SHTB50/3 | 2×22 | 380 | 50 | 2900 | 875 | 1015 | 1670 | 5″ | 4″ | 40 – 104 | 120 – 90 |
SHTC50/3 | 3×22 | 380 | 50 | 2900 | 1350 | 1015 | 1670 | 6″ | 5″ | 60 – 156 | 120 – 90 |
SHTA50/4 | 1×22 | 380 | 50 | 2900 | 435 | 800 | 1720 | 2½ | 2″ | 20 – 50 | 130 – 100 |
SHTB50/4 | 2×22 | 380 | 50 | 2900 | 875 | 1015 | 1720 | 5″ | 4″ | 40 – 100 | 130 – 100 |
SHTC50/4 | 3×22 | 380 | 50 | 2900 | 1350 | 1015 | 1720 | 6″ | 5″ | 60 – 150 | 130 – 100 |
SHTA50/4 | 1×30 | 380 | 50 | 2900 | 435 | 800 | 1750 | 2½ | 2″ | 25 – 50 | 160 – 100 |
SHTB50/4 | 2×30 | 380 | 50 | 2900 | 875 | 1015 | 1750 | 5″ | 4″ | 50 – 100 | 160 – 100 |
SHTC50/4 | 3×30 | 380 | 50 | 290 | 1350 | 1015 | 1750 | 6″ | 5″ | 75 – 150 | 160 – 100 |
SHT65 A
SHT65 B
SHT65 C
DESCRIPTION AND USAGE AREAS
Vertical shaft water booster systems, which provide regular and continuous water according to the required pressure at the determined pressures, are used in schools, hospitals, workplaces, public housing, hotels. Consult your company for any multi-pump systems and water booster. It is manufactured at frequencies of 50 Hz and 60 Hz.
MOTOR | POMPA | ||||||||||
TİP | KW | V | Hz | d/d | W mm | L mm | H mm | KOLLEKTÖR GİRİŞ | KOLLEKTÖR ÇIKIŞ | MAX DEBİ m³/h | KAPASİTE mss |
SHTA65/2 | 1×30 | 380 | 50 | 2900 | 435 | 800 | 1539 | 3″ | 2½ | 45 – 75 | 75 – 60 |
SHTB65/2 | 2×30 | 380 | 50 | 2900 | 975 | 1570 | 1539 | 6″ | 5″ | 90 – 150 | 75 – 60 |
SHTC65/2 | 3×30 | 380 | 50 | 2900 | 1466 | 1570 | 1539 | 8″ | 6″ | 135 – 225 | 75 – 60 |
SHTA65/2 | 1×37 | 380 | 50 | 2900 | 435 | 800 | 1559 | 3″ | 2½ | 30 – 100 | 100 – 80 |
SHTB65/2 | 2×37 | 380 | 50 | 2900 | 975 | 1570 | 1559 | 6″ | 5″ | 60 – 200 | 100 – 80 |
SHTC65/2 | 3×37 | 380 | 50 | 2900 | 1466 | 1570 | 1559 | 8″ | 6″ | 90 – 300 | 100 – 80 |
SHTA65/3 | 1×45 | 380 | 50 | 2900 | 435 | 800 | 1702 | 3″ | 2½ | 50 – 80 | 130 – 120 |
SHTB65/3 | 2×45 | 380 | 50 | 2900 | 975 | 1015 | 1702 | 6″ | 5″ | 100 – 160 | 130 – 120 |
SHTC65/3 | 3×45 | 380 | 50 | 2900 | 1466 | 1015 | 1702 | 8″ | 6″ | 150 – 240 | 130 – 120 |
SHTA65/3 | 1×55 | 380 | 50 | 2900 | 435 | 800 | 1702 | 3″ | 2½ | 50 – 90 | 150 – 135 |
SHTB65/3 | 2×55 | 380 | 50 | 2900 | 975 | 1015 | 170 | 6″ | 5″ | 100 – 180 | 150 – 135 |
SHTC65/3 | 3×55 | 380 | 50 | 2900 | 1466 | 1015 | 1702 | 8″ | 6″ | 150 – 270 | 150 – 135 |
Vertical Multistage Booster Sets
Vertical Shaft Multistage Pumps produced by turkish vertical multistage booster manufacturers are products that make it easier to use in places where there is a horizontal space problem, they are used for hydrophore purposes, The pumps are designed with more than one impeller and stage on a vertical shaft. Although the material of the pump booster’s manufactured by turkish booster producers impeller is usually noryl, they can also be manufactured as stainless and cast. Such pumps can also be used as fire pumps in small businesses. The asynchronous motor driving the pump is designed to be on the top of the pump, the pump is usually connected to the system with an easy mounting apparatus called a glen (flange) and can be easily disassembled in case of maintenance.
Booster systems from turkish booster suppliers are used in industries, hospitals, residential units, hotels, mass housing, gas stations, holiday villages, shopping malls, social facilities, fire systems for booster purposes and pressurized water needs.
Hydrophore from turkish hydrophore suppliers are electrically powered water pumps produced for the purpose of increasing the water pressure.
Regarding the selection of booster set, it should be known that , With the help of the working principle of the booster, high pressure, they deliver the water they suck from a certain water reservoir to far points. Thanks to the expansion tanks connected to the boosters, they already hold pressurized water.
Pressurized Water Boosters manufactured by turkish booster producers are used in buildings, apartments, detached villas, estates and high-rise buildings to meet the need for mains water or pressurized water from tanks in cases where the mains water pressure is not sufficient. In short, we can say that it is a water pressurization system used wherever the water pressure is insufficient. These systems, most of which work with electricity, increase the pressure of the water flowing from our taps.
Regarding the selection of the boosters , it should be known that , The difference between the booster and the pump is a detail that is often wondered. Let’s briefly explain this as follows. The booster is a whole system consisting of both the pump and the control equipment that controls the pump’s input and output.
The Booster Pump has a system consisting of protection equipment in order to ensure its long-lasting operation, so that it does not focus on a single purpose, the system in general provides control and protection.
Vertical Multistage Booster produced by turkish booster manufacturers is the name given to the pumps that are automatically activated when the water supply is insufficient. It pressurizes the water in the water tank with the pump wheels and pumps it to the far point, in short, this is the working principle. The selection of the booster pump should be completely tailored to the needs; It should be able to give the pressure to the water to go to the desired place. The booster is not only a system consisting of a water tank and a pump, but also has auxiliary elements mounted. We can count these auxiliary elements as follows; Expansion Tank, Manometer, Check Valve, Ball Valve, Pressure Switch, Control Panel and Water Level Floater.
There are some points when calculating the Gradual Booster; the number of flats and the height of the building, the location of the warehouse, the horizontal and vertical pipes in the building installation, the friction coefficient of the water in the water installation, the water supply for how many flats, the distance between the flats to be installed and the flats to be fed, etc. These details are important for choosing the right booster and provide long-term usefulness.